| Product
Series |
PowerVarioTM I-6kVA |
PowerValueTM |
| Description |
Multifunctial
UPS series for single phase uniterruptible power supply for Server, Network,
Storage, VoIP and Telecommunication application. Can be used as a stand-alone
or 19" Rack configuration with Newave connectivity options. |
The Beauty of Power Protection Simplicity address to mid-sized
server rooms, networks, telecommunications systems, industrial processes and
medical equipment where high cost parallelable or scalable power protection
solutions are not required. |
| Model |
PowerVario TM |
PowerValueTM I I |
PowerValueTM 3 I |
PowerValueTM 33 |
| Cabinet
type |
19" rack or tower
version combined |
Stand Alone |
Stand Alone |
Stand Alone |
| Model
rating in kVA |
I up to 6kVA |
7,5 up to I 2kVA |
7,5 up to 40kVA |
7,5 up to 40kVA |
| Individual
power range per module |
- |
- |
- |
- |
| Maximum
power per frame |
- |
- |
- |
- |
| Maximum
power per frame with n+ I Redundancy |
- |
- |
- |
- |
| Parallelable
up to |
4pcs of 4.5 and 6kVA |
- |
- |
- |
| Rated
output voltage |
220/230/240V single phase |
220/230/240V single phase |
220/230/240V single phase |
380/220; 400/230; 415/240V
thre phase |
| Classification
according IEC/EN 62040-3 |
VFI-SS- I I I |
VFI-SS- I I I |
VFI-SS- I I I |
VFI-SS- I I I |
| Working
mode |
on-line double conversion |
on-line double conversion |
on-line double conversion |
on-line double conversion |
| Efficiency |
up to 92% |
up to 92% |
up to 92% |
up to 92% |
| Poer
density per m2 |
up to 3 kVA per HE
(19") |
up to 44kVA/m2 |
up to 82kVA/m2 |
up to 82kVA/m2 |
| Max.weight
w/out batteries depending on cabinet type |
up to 29.7kg |
up to 204 kg |
up to 204 kg |
up to 204 kg |
| Standard
autonomy times |
up to I h |
up to I h |
up to I h |
up to I h |
| Battery
monitoring |
standard |
standard |
standard |
standard |
| Battery
compartment |
included in UPS cabinet |
included in UPS cabinet |
included in UPS cabinet |
included in UPS cabinet |
| Maintenance
by-pass |
option |
standard |
standard |
standard |
| Slot
for connectivity |
integrated |
integrated |
integrated |
integrated |
| Connectivity
cards SNMP/Modbus/Contacts |
optional |
optional |
optional |
optional |
| RS-232
port |
standard |
standard |
standard |
standard |
| Input
current distorsion < 8 % THDI |
standard |
standard |
optional (12%) |
optional (12%) |
| Input
current distorsion < 5 % THDI |
standard |
- |
- |
- |
| Input
powre factor correction (PFC) |
standard |
standard |
standard |
standard |
| Scaleable |
- |
- |
- |
- |
| Modular |
only 4.5 and 6kVA |
- |
- |
- |
| N+
I capable |
only 4.5 and 6kVA |
- |
- |
- |
| Safe-Swap
modular |
only 4.5 and 6kVA |
- |
- |
- |
| maintenance
and repair w/out any load interruption and w/out switching to row mains |
- |
- |
- |
- |
| Central
monitoring through NewavewatchTM via TCP/IP, analogue, ISDN or GSM |
- |
- |
- |
- |
| |
|
|
|
|
| Phase |
SINGLE PHASE |
|
|
|
|
|